InfraWorks 360 2017.2 Update


Autodesk has released an update for InfraWorks 360.  The issues that were resolved are listed below…

Bridge Design

  • A bridge must have 8 or less girders per girder group for deck haunches to be supported.
  • Haunches are not supported if a girder crosses the centerline of the bridge deck. Therefore using an odd number of girders will not allow for haunches unless you offset the center girder from the center of the bridge deck.

Design Views

  • If you are in Engineering View and have Show Sky disabled in View Settings, the sky will becomes visible again if you switch proposals. Toggle to Conceptual View then back to Engineering View to re-disable the display of the sky background.
  • Some component textures, such as the bridge component deck texture, can be difficult to see using the default Conceptual View settings. To improve texture visibility, adjust model time in Sun & Sky settings, or reduce light intensity in the Visualization tab of the View Settings panel. You can also switch to Engineering View.

Drainage Design

  • After creating a flood snapshot, toggling the display of the flood snapshot on and off more than once may cause your view to zoom in too far, and InfraWorks 360 will also select a piece of city furniture and show its attributes in the Stack. Single-click in canvas to de-select the city furniture object, then zoom out to see the flood snapshot area again.

Road Design

  • The workflow to generate Autodesk AutoCAD Civil 3D drawings of design roads has changed. Instead of using the Generate Civil3D Drawing intelligent tool in InfraWorks 360, open AutoCAD Civil 3D and use the Insert InfraWorks 360 Open InfraWorks 360 Model tool to bring your InfraWorks 360 data into AutoCAD Civil 3D.
  • Roadside grading materials may not display properly when fixed-slope roads intersect with fixed-width roads or planning roads.
  • Roadside grading is not fully supported for roads or intersections with unresolved geometries, and may produce unexpected results.
  • Calculating earthwork volumes is not supported nor excluded in intersections with unresolved geometry, and may produce unexpected results.
  • The Cross Section Viewer does not support viewing intersection area cross sections for left turn lanes.
  • The Cross Section Viewer does not support viewing cross sections for roundabouts.
  • Superelevation is not supported for component roads if your model uses the DMRB Metric Road Standards.
  • Right of Ways are not supported for component roads if your model uses the DMRB Metric Road Standards.

Viewing Models in a Browser

  • Bridge component parts will display a white color instead of material textures when you view an InfraWorks 360 model in a browser.
  • Bridge abutments with offsets will not display when you view an InfraWorks 360 model in a browser.
Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s